LaChromUltra - Ultra High-Speed LC |
 |
|
 |  | LaChromUltra - Ultra High-Speed LC |
Product Number:LaChromUltra Modules and Specifications
The LaChromUltra system consists of the following modules:
|
- L-2160U Pump (2 units)
- L-2200U Autosampler
- L-2300 or L-2350 Column Oven
- L-2400U UV, L-2420U UV-Vis or L-2485U FL Detector
- Organizer/Power Supply
|
- Software: EZChrom Elite™ for Hitachi
- OS: Windows XP
- Connection: USB
Specifications:
|
L-2160U Pump Specifications |
|---|
|
Liquid feed system
|
Dual-plunger reciprocating pump (series connection, pulsation suppression)
|
|---|
|
Flow rate range
|
0.001 to 5.000mL/min
|
|---|
|
Max. discharge pressure
|
60MPa (0.001 to 2.500mL/min)
|
|---|
|
Flow rate accuracy
|
±2% (0.101 to 2.500mL/min)
|
|---|
|
Flow rate precision
|
RSD 0.07% or SD 0.02min
|
|---|
|
Dimensions/weight
|
340 (W) × 400 (D) × 150 (H)mm, 15kg
|
|---|
|
Power supply
|
DC24V (supplied from organizer)
|
|---|
|
Power consumption
|
50 VA
|
|---|
|
Gradient System
|
|
|---|
|
Number of solutions mixable
|
2 solutions
|
|---|
|
Mixing system
|
2-pump flow rate control
|
|---|
|
|
L-2200U Autosampler Specifications |
|---|
|
Number of samples
|
1.5mL × 200 pcs (1mL vial and micro plate usable with optional rack)
|
|---|
|
Sample injection system
|
Direct injection
|
|---|
|
Sample injection volume
|
0.1 to 50µL
|
|---|
|
Injection volume reproducibility
|
0.3% RSD or less (when 10µL is injected)
|
|---|
|
Carryover
|
0.005% or less (under specified conditions)
|
|---|
|
Withstand pressure
|
60MPa
|
|---|
|
Sample cooling
|
Thermoelectric cooling rack optionally available
|
|---|
|
Dimensions/weight
|
340 (W) × 400 (D) × 300 (H)mm, approx. 19kg
|
|---|
|
Power supply
|
DC24V (supplied from organizer)
|
|---|
|
Power consumption
|
50 VA
|
|---|
|
|
L-2300 Column Oven Specifications |
|---|
|
Range
|
[Room temp - 15 °C] to[Room temp + 50°C]
|
|---|
|
Setting range
|
1 to 65 °C
|
|---|
|
Accuracy
|
+/- 1 °C
|
|---|
|
Safety
|
Built-in vapor/leak sensor
|
|---|
|
Stability
|
+/- 0.1 °C
|
|---|
|
Column capacity
|
Up to three 25-cm columns
|
|---|
|
GLP functions
|
Serial number registration in unit memory
|
|---|
|
Dimensions/weight
|
340 mm (W) x 400 mm (D) x 150mm (D), approx.10 kg
|
|---|
|
Power supply
|
100 V (50/60 Hz)
(organizer/AC adapter not required)
|
|---|
|
Power consumption
|
200 VA
|
|---|
|
|
L-2350 Column Oven Specifications |
|---|
|
Range
|
[Room temp- 15 °C] to [Room temp + 65 °C]
|
|---|
|
Setting range
|
1 to 85 °C
|
|---|
|
Accuracy
|
+/- 1 °C
|
|---|
|
Safety
|
Built-in vapor/leak sensor
|
|---|
|
Stability
|
+/- 0.1 °C
|
|---|
|
Column capacity
|
Up to four 50-cm columns (10 mm ID max)
|
|---|
|
GLP functions
|
Serial number registration in unit memory
|
|---|
|
Options
|
3-column selector valve 6-way 2-position valve 10-way 2-position valve Manual injector (Rheodyne 7725i)
|
|---|
|
Dimensions/weight
|
210 mm (W) x 360 mm (D) x 615 mm (H), approx. 20 kg
|
|---|
|
Power supply
|
100V (50/60Hz)
(organizer and AC adapter not required)
|
|---|
|
Power consumption
|
300VA
|
|---|
|
|
L-2400U UV Detector |
|---|
|
Optical system
|
Double-beam ratio photometry system
|
|---|
|
Light source
|
D2 lamp, Hg lamp (for wavelength check)
|
|---|
|
Flow cell
|
3.2µL (optical path length 5mm)
|
|---|
|
Measuring wavelength range
|
190 to 600nm
|
|---|
|
Wavelength accuracy
|
±1nm
|
|---|
|
Noise
|
0.6 × 10–5 AU or less (250nm, air in cell, response 2.0sec, cell length 5mm)
|
|---|
|
Drift
|
1.0 × 10–4 AU/hr or less (250nm, air in cell, response 2.0sec, constant temperature, cell length 5mm)
|
|---|
|
Response
|
0.01 to 2.0sec (7 steps)
|
|---|
|
Data sampling period
|
10msec (shortest)
|
|---|
|
Dimensions/weight
|
340 (W) × 400 (D) × 150 (H)mm, approx. 11kg
|
|---|
|
Power supply
|
DC24V (supplied from organizer)
|
|---|
|
Power consumption
|
85VA
|
|---|
|
|
L-2420U UV-Vis Detector |
|---|
|
Optical system
|
Double-beam ratio photometry system
|
|---|
|
Light source
|
D2 lamp, Hg lamp (for wavelength check)
|
|---|
|
Flow cell
|
3.2µL (optical path length 5mm)
|
|---|
|
Measuring wavelength range
|
190 to 900nm
|
|---|
|
Wavelength accuracy
|
±1nm
|
|---|
|
Noise
|
0.6 × 10–5 AU or less (250nm/600nm, air in cell, response 2.0sec, cell length 5mm)
|
|---|
|
Drift
|
1.0 × 10–4 AU/hr or less (250nm/600nm, air in cell, response 2.0sec, constant temperature, cell length 5mm)
|
|---|
|
Response
|
0.01 to 2.0sec (7 steps)
|
|---|
|
Data sampling period
|
10msec (shortest)
|
|---|
|
Dimensions/weight
|
340 (W) × 400 (D) × 150 (H)mm, approx. 11kg
|
|---|
|
Power supply
|
DC24V (supplied from organizer)
|
|---|
|
Power consumption
|
85VA
|
|---|
|
|
L-2485UFluorescence Detector |
|---|
|
Light source
|
Xe lamp, Hg lamp (for wavelength check)
|
|---|
|
Measuring wavelength range
|
Excitation side: 200 to 850nm
Emission side: 250 to 900nm (For 731nm or longer, the photomultiplier needs to be changed.)
|
|---|
|
Wavelength accuracy
|
±3nm
|
|---|
|
Spectral bandwidth
|
Excitation side: 15nm
Emission side: 15, 30nm (switchable)
|
|---|
|
Sensitivity
|
S/N ratio at Raman peak of water: 550 or better [ultra high-speed LC flow cell: 3µL (volume irradiated)] (baseline method) (Em: 30nm)
S/N ratio at Raman peak of water: 900 or better (standard flow cell)(baseline method)(Em: 30nm)(option)
|
|---|
|
Material of wetted parts
|
Quartz, fluorocarbon resin
|
|---|
|
Response
|
0.01 to 2.0sec (7 steps)
|
|---|
|
Data sampling period
|
10msec (shortest)
|
|---|
|
Dimensions/weight
|
340 (W) × 400 (D) × 300 (H)mm, approx. 23kg
|
|---|
|
Power supply
|
100 V (50/60 Hz)
(organizer and AC adapter not required)
|
|---|
|
Power consumption
|
450VA
|
|---|
|
|
Organizer |
|---|
| Output |
DC24V, 300VA Power supply to 2 pumps, 1 auto sampler and 1 detector
|
|---|
| Dimensions/weight |
340 mm (W) x 400 mm (D) x 150mm (D), approx.10 kg
|
|---|
| Power supply |
100 V (50/60 Hz)
|
|---|
|
Power consumption
|
400 VA
|
|---|
|
*EZChrom Elite™ is a registered trademark of Agilent Technologies, Inc.
|













|